StudentShare
Contact Us
Sign In / Sign Up for FREE
Search
Go to advanced search...
Free

Troubleshooting, Diagnosis and Maintenance for ENLD Air Bottle and KAM - Report Example

Summary
This report "Troubleshooting, Diagnosis and Maintenance for ENLD Air Bottle and KAM" focuses on equipment that requires proper cleaning, inspection, maintenance and replacement of the parts that have worn out. These may include engineering verifications…
Download full paper File format: .doc, available for editing
GRAB THE BEST PAPER93.6% of users find it useful

Extract of sample "Troubleshooting, Diagnosis and Maintenance for ENLD Air Bottle and KAM"

Running Head: Troubleshooting, Diagnosis and Maintenance Troubleshooting, Diagnosis and maintenance Student’s name Course/Number Date Instructor’s name Troubleshooting, Diagnosis, and Maintenance. Under normal circumstances, equipment requires proper cleaning, inspection, maintenance and replacement of the parts that have worn out. These may include engineering verifications. Maintenance is important to keep the equipment working all the time efficiently. An effective model for troubleshooting is available in the supplier manual book to optimize the running of the system. In coming pages, five different equipment used in the project are discussed in detail, regarding the troubleshooting, diagnosis, and maintenance. Dewatering water sensing probes Here we collected the most possible faults and their causes with the advised corrective actions. Problem Causes Corrective measures KAM ATD not working -Not connected to power -the antenna have failed - sensors have failed - Alarm is faulty -connect power - switch on Turn OFF/AUTO switch -replace the alarm -check connection, if faulty replace the alarm Sensor 1 fails to trigger the shutting of the MOV as oil concentrations increase -Not connected to power - sensors is faulty - power is off -wrong connections Wrong set up -mov is faulty Wrong set up -mov is faulty -make proper set up -replace the sensor Put proper cable connections Switch power on Sensor 2 fails to trigger both an alarm and the closing of the MOV. Sensor is faulty -alarm is faulty -mov is faulty - power is off -wrong connections Wrong set up Replace the Sensor Replace the alarm is Replace the mov - switch on the power -wrong connections - set the parameters correct oil emulsion drains from the tank -sensors are faulty -replace the sensors Replace the alarm is Replace the mov - switch on the power -wrong connections - set the parameters correct Comment 1: Antenna are meter reading and any fluid at the probe's antenna will influence false readings. Comment 2: this power switch with the system Comment 3: the sensor is substituted when it fails to work completely Comment 4: the alarm is linked to probe via a sites telemetry system and it is replaced with new one when it can be repaired. PLC Controller The following shows causes, problems and correction measures taken when LOGO (logic modules) is not functioning properly. Cause Corrective measures LOGO! 8(logic modules) not working -fuss - power failure - failure of the Display HMI -Ethernet failure - LCD display failure - Ethernet interface -connect power - connect internet switch -replace Fuss - replace display - Digital I/O expansion modules -network failure -connect internet - -make proper connection -replace the network card Put proper cable connections Failure of LCD display LCD display unit is faulty - Replace the LCD display Replace the alarm when it fails Failure of power -fuss is faulty -power connections is faulty -wrong cables -replace the cables -replace the fuss Replace the mov - switch on the power -wrong connections - set the parameters correct Comment 5 Ethernet interface for programing Comment 6: Ethernet switch controls programming interface Comment 7 deleted Comment 8: Ethernet connection is connectivity when using Comment 9: Ethernet card is used programming interface Comment 10: Replace the alarm when alarm fails Comment 11: a varistor is MOV and when varistor fails or produces high voltage it is replaced. Solenoid valves The following shows causes, problem and correction measures taken when solenoid valves are not functioning properly. Fault Cause Corrective measures Sоlеnоid valves not working - faulty valve balls. -replace the sоlеnоid vаlvеs sоlеnоid vаlvеs fails to open - wrong type of valve balls - faulty - Use right specification for valve balls -Repair or replace the valve balls Ball taking in liquid -having cracks Loose ends -replace balls . No-Loss air bottle drain valve. The following shows causes, problem and correction measures taken when the No-loss drain valve Is not functioning properly. Problem Cause Corrective measures ЕNLD air bottle not working - Power cord not plugged in. - Motor overload relay tripped. - Fuse blown &/or circuit breaker is tripped. - Defective pressure switch. - motor is faulty - not lubricated -Wrong power voltage. -power cord plugging in -Repair the failed components - lubricated - replace defective pressure switch - use the right power voltage Power fails function properly - use of wrong specification for cord - wrong electrical connection - insufficient power supply - Use right specification for motor -Ensure proper power supply -Repair or replace the components Fuses failure -Power outage or overload -Defective fuss -wrong size fuse or circuit breaker -have proper electrical connections. -change fuss -make proper connections – -connect uninterrupted power supply -put proper components. Noisy operation and excessive vibration -No lubrication is done -valves have mechanical errors - worn out parts - lubricate -Replace worn out parts -Tighten loose parts - Clean. Comment 12: deleted item Comment 13: replaced with “replace defective pressure switch” Comment 14: deleted Routine Maintenance Here are some advised routine maintenance checks to be done by the engineers onboard for all drain system components Tank Dewatering Inspect Daily Weekly Monthly Half annual Personnel Probe function × 4th engineer Alarm × 4th engineer Drain valve operation × 4th engineer concentrations reaching predetermined level × 2nd engineer Comment 15: Routine maintenance checks for Tank Dewatering will require probe function be checks daily as it is in use, because if it fails the system will fail. The alarm and drain valve should be checked weekly while concentrations reaching predetermined PLC Maintenance Air bottle drain Inspect Daily Weekly Monthly Half annual When it fails Personnel Drain line passage × 4th engineer Electric wires × 4th engineer Sensors × × 4th engineer Air solenoid operation × × 4th engineer Power connections × × 4th engineer Condition of the valve housing × 4th engineer Comments Comment 1: Antenna are meter reading and any fluid at the probe's antenna will influence false readings. Comment 2: this power switch with the system Comment 3: the sensor is substituted when it fails to work completely Comment 4: the alarm is linked to probe via a sites telemetry system and it is replaced with new one when it can be repaired. Comment 5 Ethernet interface for programing Comment 6: Ethernet switch controls programming interface Comment 7 deleted Comment 8: Ethernet connection is connectivity when using Comment 9: Ethernet card is used programming interface Comment 10: Replace the alarm when alarm fails Comment 11: a varistor is MOV and when varistor fails or produces high voltage it is replaced. Comment 12: deleted item Comment 13: replaced with “replace defective pressure switch” Comment 14: deleted Comment 15: Routine maintenance checks for Tank Dewatering will require probe function be checks daily as it is in use, because if it fails the system will fail. The alarm and drain valve should be checked weekly while concentrations reaching predetermined Summary There should be periodic maintenance and repairs of all mentioned equipment. Any modifications such as addition to the equipment should be carried with written sanction from the manufacturer or a qualified engineer. There should be regular inspection, testing and maintenance. The instructions should be written, and the frequency of the inspections, testing and maintenance should be based on the amount of work done by these equipment. The instructions in place should at least match the minimum requirements has laid out by the manufacturer of the equipment. Proper records of all inspection, testing and maintenance carried out on each equipment should be maintained at the workplace. Inspection should be done by trained, competent and experienced hands. These employees should be well aware of the hazards of handling these equipment and the environment in which they are operated. The supervisors should be well aware of the policies and procedures of their employers with respect to handling the equipment, and if there are any unsafe working conditions in the workplace, then they should be identified, reported and corrective action should be taken. Supervisors and managers should be perpetually alert to unsafe work conditions and take corrective steps as and when unsafe work conditions arise. Read More

CHECK THESE SAMPLES OF Troubleshooting, Diagnosis and Maintenance for ENLD Air Bottle and KAM

PC Maintenance, Troubleshooting and Diagnosis

This paper ''PC maintenance, Troubleshooting and Diagnosis'' tells that uninstalling unneeded applications, cleaning up the disk with disk cleanup, checking disk with ScanDisk and defragmenting the disk with Defragmenter are the ways to ensure that the drivers are clean and prevent loss of allocating units.... This brought to me another argument, 'would I have to hire a professional for every time I lose data or have problems with my computer', which made me take an interest in troubleshooting, maintenance and diagnosis....
7 Pages (1750 words) Research Proposal

Reliability of psychiatric diagnosis

had discovered flaws in psychiatric diagnosis and developed the DSM.... This essay will discuss the reliability of psychiatric diagnosis given the above argument.... , which calls for the need for uniformity of psychiatric diagnosis.... Unreliability of psychiatric diagnosis affects a number of activities in the health sector.... The environment also influences the diagnosis of patients.... These and other factors raise questions about the reliability of the diagnosis of psychiatrist cases....
3 Pages (750 words) Essay

Diagnosis Made Easier Chapters Critique

The essay "diagnosis Made Easier Chapters Critique" focuses on the critical analysis of the major chapters of J.... orrison's book diagnosis made easier: Principles and techniques for mental health clinicians.... The primary purpose is that this case marks the beginning of the journey towards a successful and critical diagnosis.... The foremost objectives of this chapter thus include: providing an explanation of the foundations of diagnosis, introducing the reader to the levels of diagnosis which are expounded upon later in the succeeding chapters of the book....
18 Pages (4500 words) Essay

With reference to schizophrenia, how effective is the DSM-IV-TR as a diagnostic tool

For this purpose the American Psychiatric Associations have formulated a manual that can be used by a physician for diagnosis to assess their emotional past and current symptoms.... In fact these people have gathered together to bring out the lists of criteria especially the common signs and symptoms that need to be present for a particular diagnosis to be assigned.... There are two major systems presently used for the diagnosis of schizophrenia, the Diagnostic and Statistic Manual of Mental Disorders and the International Classification of Disease....
4 Pages (1000 words) Essay

Troubleshooting Electric Circuits

In this paper, I will explain Effective troubleshooting is a stepwise procedure that can be modified depending on the system that is being dealt with.... The basic steps of troubleshooting, as I discovered, start with identifying the defect system.... The second step in basic troubleshooting is analysing the fault in the identified system.... The third step of troubleshooting is carrying out of repairs.... Considering that there a number of problems that are encountered, I narrowed my scope of study to electrical troubleshooting....
4 Pages (1000 words) Essay

Validity of Schizophrenia as a Mental Health Diagnosis

The paper "Validity of Schizophrenia as a Mental Health diagnosis" states that some diagnoses such as ICD-9 can be regarded as valid in the prediction of the disability, which may accompany some of the symptoms of this disorder.... The diagnosis of the condition through interviews and other methods involving interactions with the patient has also proved to be valid.... This form of diagnosis has proved to be valid since the results it gives help in coming up with the appropriate treatment methods....
8 Pages (2000 words) Essay

Troubleshooting of the Software or Hardware Devices

The author of this coursework "troubleshooting of the Software or Hardware Devices" describes the troubleshooting techniques.... This paper outlines basic troubleshooting techniques, differentiating between software and hardware problem, troubleshooting skills.... Most troubleshooting techniques use the process of elimination whereby the technician will follow certain steps in order to determine and resolve the problem....
8 Pages (2000 words) Coursework

SNMP for Diagnostics and Troubleshooting Network Problems

The research paper "SNMP for Diagnostics and troubleshooting Network Problems" describes the SNMP analysis program.... This activity can be monitored and analyzed through the use of SNMP properties as well as troubleshooting areas within the user's reach (Borek, et....
18 Pages (4500 words) Research Paper
sponsored ads
We use cookies to create the best experience for you. Keep on browsing if you are OK with that, or find out how to manage cookies.
Contact Us